3.9.12.3.8
{0x5034} START_INTERVAL3_0 Details
Local Address: 0x5034
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Bits
Name
Type
31..28 Reserved
RO
START_IN
27..24
RW
TERVAL3
23..20 Reserved
RO
START_IN
19..16
RW
TERVAL2
15..12 Reserved
RO
START_IN
11..8
RW
TERVAL1
Table SCU (Sensor Control Unit)-116
Reserved
Reset
Description
Value
0x0
Reserved
This designates Sequencer 3's timer operating frequency division
value.
When SEQ_MODE is "0" or "1", the set value is referred.
32.768
kHz/(PRE_DIVIDER+1)/(2^START_INTERVAL3)
0x0
Sequencer 3's operating frequency division value.
The value range that can be set to SEQ_INTERVAL3 is from 0 to 9.
When using a One-shot Sequencer corresponding to the register, 0xA
must be set.
0x0
Reserved
This designates Sequencer 2's timer operating frequency division
value.
When SEQ_MODE is "0" or "1", this set value is referred.
0x0
As for the calculating formula of the operating frequency, the range
of values that can be set, and set values when using the One-shot
Sequencer, refer to START_INTERVAL3.
0x0
Reserved
This designates Sequencer 1's timer operating frequency division
value.
When SEQ_MODE1 is "0" or "1", this set value is referred.
0x0
As for the calculating formula of the operating frequency, the range
of values that can be set, and set values when using the One-shot
Sequencer, refer to START_INTERVAL3.
-330/1010-
Register Type: RW (read/write)
Reset Value: 0x00000000
Reserved