(28) LPADC0 data rate set
(29) LPADC1 data rate set
(30) LPADC2 data rate set
(31)LPADC3 data rate set
(32)HPADC0 data rate set
(33)HPADC1 data rate set
(34)Sequencer boot wait
(35)Sequencer startup
(36)LPADC data output enable
(37)HPADC0 data output enable
(38)HPADC1 data output enable
3.9.13.2
Power Source Turn OFF
Power supply turn OFF is performed by the following procedures.
(1) LPADC data output disable
(2) HPADC0 data output disable
(3) HPADC1 data output disable
(4) Sequencer suspend
(5) Sequencer reset
(6) LPADC, HPADC operation suspend
(7) RCOSC, XOSC clock supply stop
(8) LPADC clock supply stop
(9) HPADC clock supply stop
(10) I2C clock supply stop
(11) SPI clock supply stop
(12) SCU clock supply stop
(13) HPADC power supply stop
(14) LPADC power supply stop
(15) PWD_SCU power supply stop
3.9.13.3
Sequencer Initialization
Sequencer initialization is performed by the following procedures.
(1) Sequencer, SEQ_IRAM, SEQ_DRAM power supply
(2) Sequencer reset
(3) FIFO initialization
(4) START_CTRL related register set
(5) MATH_PROC related register set
-813/1010-