Sony CXD5602 User Manual page 807

Table of Contents

Advertisement

Only *_ENABLE of this parameter can be rewritten during operation of the ADC. To rewrite only
*_ENABLE, Read/Modify/Write access is required.
The following tables shows the FIFO_IDs and the FIFOs linked to FIFO_ID.
Table SCU (Sensor Control Unit)-693 FIFO_IDs and the FIFOs linked to FIFO_ID
FIFO_ID
FIFO
0
D0_W0_S
1
D0_W1_S
2
D0_W2_S
3
D0_W3_S
4
D1_W0_S
5
D1_W1_S
6
D1_W2_S
7
D1_W3_S
8
N0_W_S
9
N1_W_S
10
N2_W_S
11
N3_W_S
12
N4_W_S
13
N5_W_S
14
N6_W_S
15
N7_W_S
3.9.12.11.10 ADC_MATH_PROC_OFST_GAIN_n
OFFSET: 0x0264 + n x 0x04 (n = 0, ..., 6)
NAME
ADC_MATH_PROC_OFST_GAIN_n
Prohibited setting at ADC_PRIORITY
Prohibited setting at ADC_PRIORITY
Prohibited setting at ADC_PRIORITY
Prohibited setting at ADC_PRIORITY
Prohibited setting at ADC_PRIORITY
Prohibited setting at ADC_PRIORITY
Table SCU (Sensor Control Unit)-694
Field Name
GAIN
-807/1010-
Bit
RW
Description
[31:30]
RW
n = 0: LPADC0 gain value (X)
n = 1: LPADC1 gain value (X)
n = 2: LPADC2 gain value (X)
n = 3: LPADC3 gain value (X)
n = 4: HPADC0 gain value (X)
n = 5: HPADC0 gain value (Y)
n = 6: HPADC1 gain value (X)
CXD5602 User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents