Related commands: alarm oam error-frame enable.
When the alarm threshold is set to 0, large amount of alarms are generated immediately. Since
alarm events are carried in the OAM packets, large amount of OAM packets are generated. In this
case, OAM packets may be lost.
The commands here take effect only for OAM 2.0 and above.
Examples
# Set the window size and alarm threshold for error frame to 20 seconds and 30 frames on ONU
1/0/1:1.
<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-frame window 20 threshold 30
alarm oam error-frame enable
Syntax
alarm oam error-frame enable
undo alarm oam error-frame enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-frame enable command to enable the error frame alarm.
Use the undo alarm oam error-frame enable command to disable the error frame alarm.
By default, this function is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error frame alarm for the ONU corresponding to ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-frame enable
4-11