Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-frame-seconds-summary enable command to enable the error frame
seconds summary alarm.
Use the undo alarm oam error-frame-seconds-summary enable command to disable the error
frame seconds summary alarm.
By default, the error frame seconds summary alarm is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error frame seconds summary alarm for the ONU corresponding to ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-frame-seconds-summary enable
alarm oam local-link-fault enable
Syntax
alarm oam local-link-fault enable
undo alarm oam local-link-fault enable
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam local-link-fault enable command to enable the local link fault alarm.
Use the undo alarm oam local-link-fault enable command to disable the local link fault alarm.
By default, the local ink fault alarm is enabled.
The system generates a local link fault alarm when the receiving direction of the local data terminal is
in trouble.
Examples
# Enable the local link fault alarm on OLT 3/0/1.
<Sysname> system-view
[Sysname] interface olt 3/0/1
4-13