Default Level
2: System level
Parameters
None
Description
Use the alarm software-error enable command to enable the software error alarm of the system.
Use the undo alarm software-error enable command to disable the software error alarm of the
system.
The system generates a software error alarm when a signal error, DA abnormity (that is, data access
abnormity) error, or memory allocation failure occurs.
By default, the software error alarm is enabled.
Examples
# Enable the software error alarm in the EPON system.
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] alarm software-error enable
monitor enable
Syntax
monitor enable
undo monitor enable
View
FTTH view
Default Level
3: Manage level
Parameters
None
Description
Use the monitor enable command to enable alarm monitor in the EPON system.
Use the undo monitor enable command to disable alarm monitor in the EPON system.
By default, alarm monitor is enabled in the EPON system.
Examples
# Enable the alarm monitor of the EPON system
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] monitor enable
sample enable
Syntax
sample enable
undo sample enable
4-17