The system generates a registration error alarm when an error occurs during the registration of an
ONU.
By default, the registration error alarm is enabled.
Examples
# Enable the registration error alarm on OLT 3/0/1.
<Sysname> system-view
[Sysname] interface olt3/0/1
[Sysname-Olt3/0/1] alarm registration-error enable

alarm remote-stable enable

Syntax
alarm remote-stable enable
undo alarm remote-stable enable
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm remote-stable enable command to enable the remote stable alarm.
Use the undo alarm remote-stable enable command to disable the remote stable alarm.
The system generates a remote stable alarm in case of an ONU misuse in the system, for example,
when an OAM 2.0 ONU and an OAM 3.3 ONU are mixed in the same system. (All ONUs in the same
system must adopt the same OAM version.)
The local stable alarm differs from the remote stable alarm in the following way:
The local stable alarm is generated at the OLT side.
The remote stable alarm is generated at the ONU side and will be reported to the OLT.
By default, the remote stable alarm is enabled.
Related commands: alarm local-stable.
Examples
# Enable the remote stable alarm on OLT 3/0/1.
<Sysname> system-view
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] alarm remote-stable enable

alarm software-error enable

Syntax
alarm software-error enable
undo alarm software-error enable