Default Level
2: System level
Parameters
threshold threshold: Specifies the alarm threshold of the LLID mismatch frame alarm. It ranges from
9
1000 to 10
frames and defaults to 5000 frames.
Description
Use the alarm llid-mismatch threshold command to configure the alarm threshold of LLID mismatch
frame.
Use the undo alarm llid-mismatch threshold command to restore the default alarm threshold.
The system generates an LLID mismatch frame alarm when the timeslots are used in disorder, that is,
one ONU uses another ONU's timeslot to forward data.
Related commands: alarm llid-mismatch enable.
Examples
# Set the alarm threshold of LLID mismatch frame to 6000 frames.
<Sysname> system-view
[Sysname] interface olt 1/0/1
[Sysname-Olt1/0/1] alarm llid-mismatch threshold 6000

alarm local-stable enable

Syntax
alarm local-stable enable
undo alarm local-stable enable
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm local-stable enable command to enable the local stable alarm.
Use the undo alarm local-stable enable command to disable the local stable alarm.
The system generates a local stable alarm in case of an ONU misuse in the system, for example, when
an OAM 2.0 ONU and an OAM 3.3 ONU are mixed in the same system. (All ONUs in the same system
must adopt the same OAM version.)
The local stable alarm differs from the remote stable alarm in the following ways:
The local stable alarm is generated at the OLT side.
The remote stable alarm is generated at the ONU side and will be reported to the OLT.
By default, this function is enabled.
Related commands: alarm remote-stable enable.