Display Stp Region-Configuration - H3C S7500E Series Command Reference Manual

Lan switching
Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

If you specify an MSTI ID, this command will display the historic port role calculation information of only
this specified MSTI by the sequence of port role calculation time.
Examples
# Display the historic port role calculation information of the card on slot 2 in MSTI 2.
<Sysname> display stp instance 2 history slot 2
--------------- STP slot 2 history trace ---------------
------------------- Instance 2
Port GigabitEthernet2/0/1
Role change
Time
Port priority : 0.00e0-fc01-6510 0 0.00e0-fc01-6510 128.1
Port GigabitEthernet2/0/2
Role change
Time
Port priority : 0.00e0-fc01-6510 0 0.00e0-fc01-6510 128.2
Table 11-7 display stp history command output description
Field
Port
Role change
Time
Port priority

display stp region-configuration

Syntax
display stp region-configuration [ | { begin | exclude | include } regular-expression ]
View
Any view
Default Level
1: Monitor level
Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see CLI Configuration in the Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays the lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
: ROOT->DESI (Aged)
: 2009/02/08 00:22:56
: ALTER->ROOT
: 2009/02/08 00:22:56
Port name
A role change of the port ("Age" means that the change was caused by expiry of the
received configuration BPDU)
Time of port role calculation
Port priority
---------------------
Description
11-15

Advertisement

Table of Contents
loading