View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default Level
2: System level
Parameters
timer-value: Hold timer setting (in centiseconds), which must be a multiple of 5 in the range of 10
(inclusive) and half of the Join timer setting (inclusive). One second equals 100 centiseconds.
Description
Use the garp timer hold command to set the GARP Hold timer for an Ethernet port, Layer-2
aggregate interface, or all ports in a port group.
Use the undo garp timer hold command to restore the default of the GARP Hold timer. This may fail if
the default is beyond the valid value range for the Hold timer.
By default, the Hold timer is set to 10 centiseconds.
Related commands: display garp timer and garp timer join.
Examples
# Set the GARP Hold timer to 15 centiseconds, assuming that the Join timer is 30 centiseconds.
<Sysname> system-view
[Sysname] interface GigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] garp timer hold 15

garp timer join

Syntax
garp timer join timer-value
undo garp timer join
View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default Level
2: System level
Parameters
timer-value: Join timer setting (in centiseconds), which must be a multiple of 5 in the range of two times
the Hold timer (inclusive) and half of the Leave timer (inclusive).
Description
Use the garp timer join command to set the GARP Join timer for an Ethernet port, Layer-2 aggregate
interface, or all ports in a port group.
Use the undo garp timer join command to restore the default of the GARP Join timer. This may fail if
the default is beyond the valid value range for the Join timer.
By default, the Join timer is set to 20 centiseconds.
Related commands: display garp timer, garp timer hold, and garp timer leave.