Appl. Functions; Cascade Controller - Danfoss VLT AQUA Drive FC 202 Programming Manual

Software version: 3.30
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Lists

4.1.21 24-** Appl. Functions 2

Param-
Parameter description
eter #
24-1* Drive Bypass
24-10
Drive Bypass Function
24-11
Drive Bypass Delay Time
4
4

4.1.22 25-** Cascade Controller

Param-
Parameter description
eter #
25-0* System Settings
25-00
Cascade Controller
25-02
Motor Start
25-04
Pump Cycling
25-05
Fixed Lead Pump
25-06
Number of Pumps
25-2* Bandwidth Settings
25-20
Staging Bandwidth
25-21
Override Bandwidth
25-22
Fixed Speed Bandwidth
25-23
SBW Staging Delay
25-24
SBW Destaging Delay
25-25
OBW Time
25-26
Destage At No-Flow
25-27
Stage Function
25-28
Stage Function Time
25-29
Destage Function
25-30
Destage Function Time
25-4* Staging Settings
25-40
Ramp Down Delay
25-41
Ramp Up Delay
25-42
Staging Threshold
25-43
Destaging Threshold
25-44
Staging Speed [RPM]
25-45
Staging Speed [Hz]
25-46
Destaging Speed [RPM]
25-47
Destaging Speed [Hz]
25-49
Staging Principle
25-5* Alternation Settings
25-50
Lead Pump Alternation
25-51
Alternation Event
25-52
Alternation Time Interval
25-53
Alternation Timer Value
25-54
Alternation Predefined Time
25-55
Alternate if Load < 50%
25-56
Staging Mode at Alternation
25-58
Run Next Pump Delay
25-59
Run on Mains Delay
25-8* Status
25-80
Cascade Status
276
®
VLT
AQUA Drive FC 202
Default value
4 set-up
[0] Disabled
2 set-ups
0 s
2 set-ups
Default value
4 set-up
ExpressionLimit
2 set-ups
[0] Direct on Line
2 set-ups
ExpressionLimit
All set-ups
ExpressionLimit
2 set-ups
2 N/A
2 set-ups
ExpressionLimit
All set-ups
100%
All set-ups
casco_staging_ban
dwidth (P2520)
All set-ups
15 s
All set-ups
15 s
All set-ups
10 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
15 s
All set-ups
ExpressionLimit
All set-ups
15 s
All set-ups
10 s
All set-ups
2 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 RPM
All set-ups
0 Hz
All set-ups
0 RPM
All set-ups
0 Hz
All set-ups
[0] Normal
All set-ups
ExpressionLimit
All set-ups
[0] External
All set-ups
24 h
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
[1] Enabled
All set-ups
[0] Slow
All set-ups
0.1 s
All set-ups
0.5 s
All set-ups
0 N/A
All set-ups
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
TRUE
0
Change during
Conversion
operation
index
FALSE
-
FALSE
-
TRUE
-
FALSE
-
FALSE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-1
TRUE
-1
TRUE
0
TRUE
0
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
FALSE
-
TRUE
-
TRUE
-
TRUE
74
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-1
TRUE
-1
TRUE
0
Type
Uint8
Uint16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint16
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
VisStr[7]
TimeOfDay-
WoDate
Uint8
Uint8
Uint16
Uint16
VisStr[25]
MG20OB02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents