Parameter Lists

4.1.13 14-** Special Functions

Param-
Parameter description
eter #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
14-03
Overmodulation
4
4
14-04
PWM Random
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-16
Kin. Backup Gain
14-2* Reset Functions
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
14-31
Current Lim Ctrl, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimizing
14-40
VT Level
14-41
AEO Minimum Magnetization
14-42
Minimum AEO Frequency
14-43
Motor Cosphi
14-5* Environment
14-50
RFI Filter
14-51
DC Link Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-56
Capacitance Output Filter
14-57
Inductance Output Filter
14-58
Voltage Gain Filter
14-59
Actual Number of Inverter Units
14-6* Auto Derate
14-60
Function at Over Temperature
14-61
Function at Inverter Overload
14-62
Inv. Overload Derate Current
14-8* Options
14-80
Option Supplied by External 24VDC
14-9* Fault Settings
14-90
Fault Level
264
®
VLT
AQUA Drive FC 202
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] On
All set-ups
[0] Off
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
[3] Derate
All set-ups
100%
All set-ups
[10] Automatic
reset x 10
All set-ups
10 s
All set-ups
[0] Normal
operation
All set-ups
ExpressionLimit
2 set-ups
60 s
All set-ups
ExpressionLimit
All set-ups
[0] No action
All set-ups
0 N/A
All set-ups
100%
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
66%
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] On
1 set-up
ExpressionLimit
All set-ups
[0] Auto
All set-ups
[1] Warning
All set-ups
[0] No Filter
1 set-up
2 uF
1 set-up
7 mH
1 set-up
100%
All set-ups
ExpressionLimit
1 set-up
[1] Derate
All set-ups
[1] Derate
All set-ups
95%
All set-ups
[0] No
2 set-ups
ExpressionLimit
1 set-up
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
TRUE
-
FALSE
-
TRUE
-
FALSE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
0
FALSE
0
FALSE
-3
FALSE
-4
FALSE
0
TRUE
0
TRUE
0
TRUE
-2
FALSE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
-7
FALSE
-6
TRUE
0
FALSE
0
TRUE
-
TRUE
-
TRUE
0
FALSE
-
TRUE
-
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint32
Uint8
Uint16
Uint8
Uint16
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
MG20OB02