Parameter Lists
4.1.25 30-** Special Features
Param-
Parameter description
eter #
30-2* Adv. Start Adjust
30-22
Locked Rotor Detection
30-23
Locked Rotor Detection Time [s]
30-5* Unit Configuration
30-50
Heat Sink Fan Mode
30-8* Compatibility (I)
30-81
Brake Resistor (ohm)
4.1.26 31-** Bypass Option
Param-
Parameter description
eter #
31-00
Bypass Mode
31-01
Bypass Start Time Delay
31-02
Bypass Trip Time Delay
31-03
Test Mode Activation
31-10
Bypass Status Word
31-11
Bypass Running Hours
31-19
Remote Bypass Activation
4.1.27 35-** Sensor Input Option
Param-
Parameter description
eter #
35-0* Temp. Input Mode
35-00
Term. X48/4 Temperature Unit
35-01
Term. X48/4 Input Type
35-02
Term. X48/7 Temperature Unit
35-03
Term. X48/7 Input Type
35-04
Term. X48/10 Temperature Unit
35-05
Term. X48/10 Input Type
35-06
Temperature Sensor Alarm Function
35-1* Temp. Input X48/4
35-14
Term. X48/4 Filter Time Constant
35-15
Term. X48/4 Temp. Monitor
35-16
Term. X48/4 Low Temp. Limit
35-17
Term. X48/4 High Temp. Limit
35-2* Temp. Input X48/7
35-24
Term. X48/7 Filter Time Constant
35-25
Term. X48/7 Temp. Monitor
35-26
Term. X48/7 Low Temp. Limit
35-27
Term. X48/7 High Temp. Limit
35-3* Temp. Input X48/10
35-34
Term. X48/10 Filter Time Constant
35-35
Term. X48/10 Temp. Monitor
35-36
Term. X48/10 Low Temp. Limit
35-37
Term. X48/10 High Temp. Limit
35-4* Analog Input X48/2
35-42
Term. X48/2 Low Current
MG20OB02
Programming Guide
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
All set-ups
Default value
4 set-up
[0] Drive
All set-ups
30 s
All set-ups
0 s
All set-ups
[0] Disabled
All set-ups
0 N/A
All set-ups
0 h
All set-ups
[0] Disabled
2 set-ups
Default value
4 set-up
[60] °C
All set-ups
[0] Not Connected
All set-ups
[60] °C
All set-ups
[0] Not Connected
All set-ups
[60] °C
All set-ups
[0] Not Connected
All set-ups
[5] Stop and trip
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
4 mA
All set-ups
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
TRUE
-2
TRUE
-
TRUE
-2
Change during
Conversion
operation
index
TRUE
-
TRUE
0
TRUE
0
TRUE
-
FALSE
0
FALSE
74
TRUE
-
Change during
Conversion
operation
index
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-3
TRUE
-
TRUE
0
TRUE
0
TRUE
-3
TRUE
-
TRUE
0
TRUE
0
TRUE
-3
TRUE
-
TRUE
0
TRUE
0
TRUE
-5
Type
Uint8
Uint8
4
4
uint8
Uint32
Type
Uint8
Uint16
Uint16
Uint8
V2
Uint32
Uint8
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Int16
Int16
Uint16
Uint8
Int16
Int16
Uint16
Uint8
Int16
Int16
Int16
281
Need help?
Do you have a question about the VLT AQUA Drive FC 202 and is the answer not in the manual?
Questions and answers