Parameter Description
3.12.7 13-9* User-defined Alerts and
Readouts
Parameters in this group allow the configuration of
application-specific messages, warnings, and alarms.
3
3
Use the following parameters to configure the frequency
converter to show a message and perform an action when
a specific event occurs:
Parameter 13-90 Alert Trigger – the event that
triggers the user-defined action and message.
Parameter 13-91 Alert Action – the action that the
frequency converter performs when the event
defined in parameter 13-90 Alert Trigger occurs.
Parameter 13-92 Alert Text – the text that the
frequency converter shows in the display when
the event defined in parameter 13-90 Alert Trigger
occurs.
For example, consider the following use case:
If there is an active signal on digital input 32, the
frequency converter shows the message Valve 5 open and
ramps down to a stop.
To achieve this configuration, make the following settings:
Parameter 13-90 Alert Trigger = [37] Digital input
DI32.
Parameter 13-91 Alert Action = [5] Stop & warning.
Parameter 13-92 Alert Text = Valve 5 open.
13-90 Alert Trigger
Array [10]
Select the event that triggers the user-defined action and
message.
Option:
[0]
*
[1]
[18]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[32]
[33]
[34]
[35]
[36]
[37]
[38]
[50]
[51]
130
VLT
Function:
False
True
Reversing
Comparator 0
Comparator 1
Comparator 2
Comparator 3
Logic rule 0
Logic rule 1
Logic rule 2
Logic rule 3
SL Time-out 0
SL Time-out 1
SL Time-out 2
Digital input DI18
Digital input DI19
Digital input DI27
Digital input DI29
Digital input DI32
Digital input DI33
Comparator 4
Comparator 5
Danfoss A/S © 05/2018 All rights reserved.
®
AQUA Drive FC 202
13-90 Alert Trigger
Array [10]
Select the event that triggers the user-defined action and
message.
Option:
[60]
[61]
[70]
[71]
[72]
[73]
[74]
[90]
[91]
13-91 Alert Action
Array [10]
Select the action that the frequency converter performs when
the event defined in parameter 13-90 Alert Trigger occurs.
Option:
[0]
*
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
13-92 Alert Text
Range:
Size
related
*
13-97 Alert Alarm Word
Range:
0
[0 - 4294967295 ] Shows the alarm word of a user-defined
*
13-98 Alert Warning Word
Range:
0
[0 - 4294967295 ] Shows the warning word of a user-
*
Logic rule 4
Logic rule 5
SL Time-out 3
SL Time-out 4
SL Time-out 5
SL Time-out 6
SL Time-out 7
ECB Drive Mode
ECB Bypass Mode
Info
Warning
Freeze output
Freeze output & warn
Stop
Stop & warning
Jogging
Jogging & warning
Max speed
Max speed & warn
Stop and trip
Stop and trip w manual
reset
Trip
Trip w manual reset
Trip Lock
Function:
[0 -
Array [10]
20 ]
Enter the text that the frequency
converter shows in the display when the
event defined in parameter 13-90 Alert
Trigger occurs.
Function:
alarm in hex code.
Function:
defined alarm in hex code.
Function:
Function:
MG20OB02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents