Parameter Lists

4.1.17 20-** Drive Closed Loop

Param-
Parameter description
eter #
20-0* Feedback
20-00
Feedback 1 Source
20-01
Feedback 1 Conversion
20-02
Feedback 1 Source Unit
4
4
20-03
Feedback 2 Source
20-04
Feedback 2 Conversion
20-05
Feedback 2 Source Unit
20-06
Feedback 3 Source
20-07
Feedback 3 Conversion
20-08
Feedback 3 Source Unit
20-12
Reference/Feedback Unit
20-2* Feedback/Setpoint
20-20
Feedback Function
20-21
Setpoint 1
20-22
Setpoint 2
20-23
Setpoint 3
20-6* Sensorless
20-60
Sensorless Unit
20-69
Sensorless Information
20-7* PID Autotuning
20-70
Closed Loop Type
20-71
PID Performance
20-72
PID Output Change
20-73
Minimum Feedback Level
20-74
Maximum Feedback Level
20-79
PID Autotuning
20-8* PID Basic Settings
20-81
PID Normal/ Inverse Control
20-82
PID Start Speed [RPM]
20-83
PID Start Speed [Hz]
20-84
On Reference Bandwidth
20-9* PID Controller
20-91
PID Anti Windup
20-93
PID Proportional Gain
20-94
PID Integral Time
20-95
PID Differentiation Time
20-96
PID Diff. Gain Limit
270
®
VLT
AQUA Drive FC 202
Default value
4 set-up
[2] Analog Input 54
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[4] Maximum
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
[0] Auto
2 set-ups
[0] Normal
2 set-ups
0.10 N/A
2 set-ups
-999999
ProcessCtrlUnit
2 set-ups
999999
ProcessCtrlUnit
2 set-ups
[0] Disabled
All set-ups
[0] Normal
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5%
All set-ups
[1] On
All set-ups
2 N/A
All set-ups
8 s
All set-ups
0 s
All set-ups
5 N/A
All set-ups
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
FALSE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
67
TRUE
-1
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-1
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Int32
Int32
Uint8
VisStr[25]
Uint8
Uint8
Uint16
Int32
Int32
Uint8
Uint8
Uint16
Uint16
Uint8
Uint8
Uint16
Uint32
Uint16
Uint16
MG20OB02