Danfoss VLT AQUA Drive FC 202 Programming Manual page 33

Software version: 3.30
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Description
0-20 Display Line 1.1 Small
Option:
Function:
[1613]
Frequency
Motor frequency, that is the output
frequency from the frequency converter
in Hz.
[1614]
Motor Current
Phase current of the motor measured as
effective value.
[1615]
Frequency [%]
Motor frequency, that is the output
frequency from the frequency converter
in percent.
[1616]
Torque [Nm]
Present motor load as a percentage of
the rated motor torque.
[1617]
Speed [RPM]
Speed in RPM (revolutions per minute),
that is the motor shaft speed in closed
*
loop based on the entered motor
nameplate data, the output frequency,
and the load on the frequency
converter.
[1618]
Motor Thermal
Thermal load on the motor calculated
by the ETR function. See also parameter
group 1-9* Motor Temperature.
[1619]
KTY sensor
temperature
[1620]
Motor Angle
[1622]
Torque [%]
Shows the actual torque produced in
percentage.
[1625]
Torque [Nm]
High
[1630]
DC Link
DC-link voltage in the frequency
Voltage
converter.
[1632]
Brake Energy /s Present brake power transferred to an
external brake resistor.
Shows an instant value.
[1633]
Brake
Brake power transferred to an external
Energy /2 min
brake resistor. The average power is
calculated continuously for the most
recent 120 s.
[1634]
Heatsink Temp. Present heat sink temperature of the
frequency converter. The cutout limit is
95 ±5 °C. Cutting back in occurs at 70
±5 °C.
[1635]
Inverter
Percentage load of the inverters.
Thermal
[1636]
Inv. Nom.
Nominal current of the frequency
Current
converter.
[1637]
Inv. Max.
Maximum current of the frequency
Current
converter.
[1638]
SL Controller
State of the event executed by the
State
control.
[1639]
Control Card
Temperature of the control card.
Temp.
MG20OB02
Programming Guide
0-20 Display Line 1.1 Small
Option:
[1650]
[1651]
[1652]
[1653]
[1660]
[1661]
[1662]
[1663]
[1664]
[1665]
[1666]
[1667]
[1668]
[1669]
[1670]
[1671]
[1672]
[1673]
[1674]
[1675]
Danfoss A/S © 05/2018 All rights reserved.
Function:
External
Sum of the external reference as a
Reference
percentage, that is the sum of analog,
pulse, and bus.
Pulse
Reference
Feedback [Unit] Signal value in units from the
programmed digital inputs.
Digi Pot
View the contribution of the digital
Reference
potentiometer to the actual reference
feedback.
Digital Input
Shows the status of the digital inputs.
Signal low=0, signal high=1.
Regarding order, see
parameter 16-60 Digital Input. Bit 0 is at
the extreme right.
Terminal 53
Setting of input terminal 53. Current=0,
Switch Setting
voltage=1.
Analog Input
Actual value at input 53 either as a
53
reference or protection value.
Terminal 54
Setting of input terminal 54. Current=0,
Switch Setting
voltage=1.
Analog Input
Actual value at input 54 either as
54
reference or protection value.
Analog Output
Actual value at output 42 in mA. Use
42 [mA]
parameter 6-50 Terminal 42 Output to
select the variable to be show in output
42.
Digital Output
Binary value of all digital outputs.
[bin]
Freq. Input #29
Actual value of the frequency applied at
[Hz]
terminal 29 as a pulse input.
Freq. Input #33
Actual value of the frequency applied at
[Hz]
terminal 33 as a pulse input.
Pulse Output
Actual value of pulses applied to
#27 [Hz]
terminal 27 in digital output mode.
Pulse Output
Actual value of pulses applied to
#29 [Hz]
terminal 29 in digital output mode.
Relay Output
View the setting of all relays.
[bin]
Counter A
View the present value of counter A.
Counter B
View the present value of counter B.
Prec. Stop
Counter
Analog In
Actual value of the signal on input
X30/11
®
X30/11 (VLT
General Purpose I/O MCB
101, optional).
3
3
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents