Parameter Lists
4.1.2 0-** Operation/Display
Param-
Parameter description
eter #
0-0* Basic Settings
0-01
Language
0-02
Motor Speed Unit
0-03
Regional Settings
0-04
Operating State at Power-up
0-05
Local Mode Unit
0-1* Set-up Operations
0-10
Active Set-up
0-11
Programming Set-up
0-12
This Set-up Linked to
0-13
Readout: Linked Set-ups
0-14
Readout: Prog. Set-ups/Channel
0-2* LCP Display
0-20
Display Line 1.1 Small
0-21
Display Line 1.2 Small
0-22
Display Line 1.3 Small
0-23
Display Line 2 Large
0-24
Display Line 3 Large
0-25
My Personal Menu
0-3* LCP Custom Readout
0-30
Custom Readout Unit
0-31
Custom Readout Min Value
0-32
Custom Readout Max Value
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-41
[Off] Key on LCP
0-42
[Auto on] Key on LCP
0-43
[Reset] Key on LCP
0-44
[Off/Reset] Key on LCP
0-45
[Drive Bypass] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password
0-61
Access to Main Menu w/o Password
0-65
Personal Menu Password
Access to Personal Menu w/o
0-66
Password
0-67
Bus Password Access
0-7* Clock Settings
0-70
Date and Time
0-71
Date Format
0-72
Time Format
0-74
DST/Summertime
MG20OB02
Programming Guide
Default value
4 set-up
[0] English
1 set-up
[0] RPM
2 set-ups
[0] International
2 set-ups
[0] Resume
All set-ups
[0] As Motor Speed
Unit
2 set-ups
[1] Set-up 1
1 set-up
[9] Active Set-up
All set-ups
[0] Not linked
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
1601
All set-ups
1662
All set-ups
1614
All set-ups
1613
All set-ups
1652
All set-ups
ExpressionLimit
1 set-up
[1] %
All set-ups
ExpressionLimit
All set-ups
100 CustomRea-
doutUnit
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[0] No copy
All set-ups
[0] No copy
All set-ups
100 N/A
1 set-up
[0] Full access
1 set-up
200 N/A
1 set-up
[0] Full access
1 set-up
0 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
1 set-up
ExpressionLimit
1 set-up
[0] Off
1 set-up
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
FALSE
-
FALSE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
Type
Uint8
Uint8
Uint8
4
4
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Int32
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Int32
Int32
VisStr[25]
VisStr[25]
VisStr[25]
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int16
Uint8
Uint16
Uint8
Uint16
TimeOfDay
Uint8
Uint8
Uint8
249