Parameter Description
0-20 Display Line 1.1 Small
Option:
[1676]
Analog In
X30/12
3
3
[1677]
Analog Out
X30/8 [mA]
[1678]
Analog Out
X45/1 [mA]
[1679]
Analog Out
X45/3 [mA]
[1680]
Fieldbus CTW
1
[1682]
Fieldbus REF 1
[1684]
Comm. Option
STW
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
[1690]
Alarm Word
[1691]
Alarm Word 2
[1692]
Warning Word
[1693]
Warning Word
2
[1694]
Ext. Status
Word
[3401]
PCD 1 Write to
MCO
[3402]
PCD 2 Write to
MCO
[3403]
PCD 3 Write to
MCO
[3404]
PCD 4 Write to
MCO
[3405]
PCD 5 Write to
MCO
[3406]
PCD 6 Write to
MCO
[3407]
PCD 7 Write to
MCO
[3408]
PCD 8 Write to
MCO
32
®
VLT
AQUA Drive FC 202
Function:
Actual value of the signal on input
®
X30/12 (VLT
General Purpose I/O MCB
101, optional).
Actual value at output X30/8 (VLT
General Purpose I/O MCB 101, optional).
Use parameter 6-60 Terminal X30/8
Output to select the variable to be
shown.
Control word (CTW) received from the
fieldbus.
Main reference value sent with control
word via the serial communications
network, for example, from the BMS,
PLC, or another controller.
Extended fieldbus communication
option status word.
Control word (CTW) received from the
fieldbus.
Status word (STW) sent to the fieldbus.
One or more alarms in hex code (used
for serial communication).
One or more alarms in hex code (used
for serial communication).
One or more warnings in hex code
(used for serial communication).
One or more warnings in hex code
(used for serial communication).
One or more status conditions in hex
code (used for serial communication).
Danfoss A/S © 05/2018 All rights reserved.
0-20 Display Line 1.1 Small
Option:
[3409]
PCD 9 Write to
MCO
[3410]
PCD 10 Write
to MCO
®
[3421]
PCD 1 Read
from MCO
[3422]
PCD 2 Read
from MCO
[3423]
PCD 3 Read
from MCO
[3424]
PCD 4 Read
from MCO
[3425]
PCD 5 Read
from MCO
[3426]
PCD 6 Read
from MCO
[3427]
PCD 7 Read
from MCO
[3428]
PCD 8 Read
from MCO
[3429]
PCD 9 Read
from MCO
[3430]
PCD 10 Read
from MCO
[3440]
Digital Inputs
[3441]
Digital Outputs
[3450]
Actual Position
[3451]
Commanded
Position
[3452]
Actual Master
Position
[3453]
Slave Index
Position
[3454]
Master Index
Position
[3455]
Curve Position
[3456]
Track Error
[3457]
Synchronizing
Error
[3458]
Actual Velocity
[3459]
Actual Master
Velocity
[3460]
Synchronizing
Status
[3461]
Axis Status
[3462]
Program Status
[3470]
MCO Alarm
Word 1
[3471]
MCO Alarm
Word 2
[9913]
Idle time
Function: