Analog I/O Option - Danfoss VLT AQUA Drive FC 202 Programming Manual

Software version: 3.30
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Lists
Param-
Parameter description
eter #
25-81
Pump Status
25-82
Lead Pump
25-83
Relay Status
25-84
Pump ON Time
25-85
Relay ON Time
25-86
Reset Relay Counters
25-9* Service
25-90
Pump Interlock
25-91
Manual Alternation

4.1.23 26-** Analog I/O Option

Param-
Parameter description
eter #
26-0* Analog I/O Mode
26-00
Terminal X42/1 Mode
26-01
Terminal X42/3 Mode
26-02
Terminal X42/5 Mode
26-1* Analog Input X42/1
26-10
Terminal X42/1 Low Voltage
26-11
Terminal X42/1 High Voltage
26-14
Term. X42/1 Low Ref./Feedb. Value
26-15
Term. X42/1 High Ref./Feedb. Value
26-16
Term. X42/1 Filter Time Constant
26-17
Term. X42/1 Live Zero
26-2* Analog Input X42/3
26-20
Terminal X42/3 Low Voltage
26-21
Terminal X42/3 High Voltage
26-24
Term. X42/3 Low Ref./Feedb. Value
26-25
Term. X42/3 High Ref./Feedb. Value
26-26
Term. X42/3 Filter Time Constant
26-27
Term. X42/3 Live Zero
26-3* Analog Input X42/5
26-30
Terminal X42/5 Low Voltage
26-31
Terminal X42/5 High Voltage
26-34
Term. X42/5 Low Ref./Feedb. Value
26-35
Term. X42/5 High Ref./Feedb. Value
26-36
Term. X42/5 Filter Time Constant
26-37
Term. X42/5 Live Zero
26-4* Analog Out X42/7
26-40
Terminal X42/7 Output
26-41
Terminal X42/7 Min. Scale
26-42
Terminal X42/7 Max. Scale
26-43
Terminal X42/7 Bus Control
26-44
Terminal X42/7 Timeout Preset
26-5* Analog Out X42/9
26-50
Terminal X42/9 Output
26-51
Terminal X42/9 Min. Scale
26-52
Terminal X42/9 Max. Scale
26-53
Terminal X42/9 Bus Control
26-54
Terminal X42/9 Timeout Preset
26-6* Analog Out X42/11
MG20OB02
Programming Guide
Default value
4 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 h
All set-ups
0 h
All set-ups
[0] Do not reset
All set-ups
[0] Off
All set-ups
0 N/A
All set-ups
Default value
4 set-up
[1] Voltage
All set-ups
[1] Voltage
All set-ups
[1] Voltage
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 N/A
All set-ups
100 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 N/A
All set-ups
100 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 N/A
All set-ups
100 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
[0] No operation
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
1 set-up
[0] No operation
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
1 set-up
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
0
TRUE
0
TRUE
0
TRUE
74
TRUE
74
TRUE
-
TRUE
-
TRUE
0
Change during
Conversion
operation
index
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
Type
VisStr[25]
Uint8
VisStr[4]
Uint32
Uint32
Uint8
4
4
Uint8
Uint8
Type
Uint8
Uint8
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
277