Analog In/Out - Danfoss VLT AQUA Drive FC 202 Programming Manual

Software version: 3.30
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Lists

4.1.8 6-** Analog In/Out

Param-
Parameter description
eter #
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-1* Analog Input 53
4
4
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
6-14
Terminal 53 Low Ref./Feedb. Value
6-15
Terminal 53 High Ref./Feedb. Value
6-16
Terminal 53 Filter Time Constant
6-17
Terminal 53 Live Zero
6-2* Analog Input 54
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-27
Terminal 54 Live Zero
6-3* Analog Input X30/11
6-30
Terminal X30/11 Low Voltage
6-31
Terminal X30/11 High Voltage
6-34
Term. X30/11 Low Ref./Feedb. Value
6-35
Term. X30/11 High Ref./Feedb. Value
6-36
Term. X30/11 Filter Time Constant
6-37
Term. X30/11 Live Zero
6-4* Analog Input X30/12
6-40
Terminal X30/12 Low Voltage
6-41
Terminal X30/12 High Voltage
6-44
Term. X30/12 Low Ref./Feedb. Value
6-45
Term. X30/12 High Ref./Feedb. Value
6-46
Term. X30/12 Filter Time Constant
6-47
Term. X30/12 Live Zero
6-5* Analog Output 42
6-50
Terminal 42 Output
6-51
Terminal 42 Output Min Scale
6-52
Terminal 42 Output Max Scale
6-53
Terminal 42 Output Bus Control
6-54
Terminal 42 Output Timeout Preset
6-55
Terminal 42 Output Filter
6-6* Analog Output X30/8
6-60
Terminal X30/8 Output
6-61
Terminal X30/8 Min. Scale
6-62
Terminal X30/8 Max. Scale
6-63
Terminal X30/8 Output Bus Control
Terminal X30/8 Output Timeout
6-64
Preset
258
®
VLT
AQUA Drive FC 202
Default value
4 set-up
10 s
All set-ups
[0] Off
All set-ups
0.07 V
All set-ups
10 V
All set-ups
4 mA
All set-ups
20 mA
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10 V
All set-ups
4 mA
All set-ups
20 mA
All set-ups
0 N/A
All set-ups
100 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 N/A
All set-ups
100 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 N/A
All set-ups
100 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
[100] Output freq.
0-100
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
1 set-up
[0] Off
1 set-up
[0] No operation
All set-ups
0%
All set-ups
100%
All set-ups
0%
All set-ups
0%
1 set-up
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-5
TRUE
-5
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-5
TRUE
-5
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
Type
Uint8
Uint8
Int16
Int16
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16