Drive Information - Danfoss VLT AQUA Drive FC 202 Programming Manual

Software version: 3.30
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Lists

4.1.14 15-** Drive Information

Param-
Parameter description
eter #
15-0* Operating Data
15-00
Operating hours
15-01
Running Hours
15-02
kWh Counter
15-03
Power Up's
15-04
Over Temp's
15-05
Over Volt's
15-06
Reset kWh Counter
15-07
Reset Running Hours Counter
15-08
Number of Starts
15-1* Data Log Settings
15-10
Logging Source
15-11
Logging Interval
15-12
Trigger Event
15-13
Logging Mode
15-14
Samples Before Trigger
15-2* Historic Log
15-20
Historic Log: Event
15-21
Historic Log: Value
15-22
Historic Log: Time
15-23
Historic log: Date and Time
15-3* Alarm Log
15-30
Alarm Log: Error Code
15-31
Alarm Log: Value
15-32
Alarm Log: Time
15-33
Alarm Log: Date and Time
15-34
Alarm Log: Setpoint
15-35
Alarm Log: Feedback
15-36
Alarm Log: Current Demand
15-37
Alarm Log: Process Ctrl Unit
15-4* Drive Identification
15-40
FC Type
15-41
Power Section
15-42
Voltage
15-43
Software Version
15-44
Ordered Typecode String
15-45
Actual Typecode String
15-46
Frequency Converter Ordering No
15-47
Power Card Ordering No
15-48
LCP Id No
15-49
SW ID Control Card
15-50
SW ID Power Card
15-51
Frequency Converter Serial Number
15-53
Power Card Serial Number
15-54
Config File Name
15-58
SmartStart Filename
15-59
Filename
15-6* Option Ident
15-60
Option Mounted
15-61
Option SW Version
MG20OB02
Programming Guide
Default value
4 set-up
0 h
All set-ups
0 h
All set-ups
0 kWh
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
0 N/A
All set-ups
0
2 set-ups
ExpressionLimit
2 set-ups
[0] False
1 set-up
[0] Log always
2 set-ups
50 N/A
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 ms
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 s
All set-ups
ExpressionLimit
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
0%
All set-ups
[0]
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
Danfoss A/S © 05/2018 All rights reserved.
Change during
Conversion
operation
index
FALSE
74
FALSE
74
FALSE
75
FALSE
0
FALSE
0
FALSE
0
TRUE
-
TRUE
-
FALSE
0
TRUE
-
TRUE
-3
TRUE
-
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
-3
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
-3
FALSE
-3
FALSE
0
FALSE
-
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TRUE
0
FALSE
0
FALSE
0
FALSE
0
Type
Uint32
Uint32
Uint32
4
4
Uint32
Uint16
Uint16
Uint8
Uint8
Uint32
Uint16
TimD
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
TimeOfDay
Uint16
Int16
Uint32
TimeOfDay
Int32
Int32
Uint8
Uint8
VisStr[6]
VisStr[20]
VisStr[20]
VisStr[5]
VisStr[40]
VisStr[40]
VisStr[8]
VisStr[8]
VisStr[20]
VisStr[20]
VisStr[20]
VisStr[10]
VisStr[19]
VisStr[16]
VisStr[20]
VisStr[16]
VisStr[30]
VisStr[20]
265