Parameter Description
[8]
Run on
reference/no
warning
3
3
[9]
Alarm
[10]
Alarm or
warning
[11]
At torque limit The torque limit set in
[12]
Out of current
range
[13]
Below current,
low
[14]
Above current,
high
[15]
Out of speed
range
[16]
Below speed,
low
[17]
Above speed,
high
[18]
Out of
feedback
range
[19]
Below
feedback low
[20]
Above
feedback high
[21]
Thermal
warning
[25]
Reverse
[26]
Bus OK
[27]
Torque limit
and stop
[28]
Brake, no
warning
[29]
Brake ready,
no fault
[30]
Brake fault
(IGBT)
82
®
VLT
AQUA Drive FC 202
Function at Stop [RPM]. The motor is
running and there are no warnings.
Motor runs at reference speed.
An alarm activates the output. There are
no warnings.
An alarm or a warning activates the
output.
parameter 4-16 Torque Limit Motor Mode
has been exceeded.
The motor current is outside the range set
in parameter 4-18 Current Limit.
Motor current is lower than the setting in
parameter 4-50 Warning Current Low.
Motor current is higher than the setting in
parameter 4-51 Warning Current High.
Output speed is outside the ranges set in
parameter 4-52 Warning Speed Low and
parameter 4-53 Warning Speed High.
Output speed is lower than the setting in
parameter 4-52 Warning Speed Low.
Output speed is higher than the setting in
parameter 4-53 Warning Speed High.
Feedback is outside the ranges set in
parameter 4-56 Warning Feedback Low and
parameter 4-57 Warning Feedback High.
Feedback is below the limit set in
parameter 4-52 Warning Speed Low.
The feedback is above the limit set in
parameter 4-56 Warning Feedback Low.
The thermal warning turns on when the
temperature exceeds the limit in the
motor, the frequency converter, the brake
resistor, or the thermistor.
Reversing. Logic 1 = relay activated, 24 V
DC when clockwise rotation of the motor.
Logic 0 = relay not activated, no signal,
when counterclockwise rotation of the
motor.
Active communication (no timeout) via the
serial communication port.
Used in performing a coast stop and in
torque limit condition. If the frequency
converter has received a stop signal and is
at the torque limit, the signal is logic 0.
The brake is active and there are no
warnings.
The brake is ready for operation and there
are no faults.
The output is logic 1 when the brake IGBT
is short-circuited. Use this function to
protect the frequency converter if there is
a fault on the brake modules. Use the
Danfoss A/S © 05/2018 All rights reserved.
output/relay to cut out the mains voltage
from the frequency converter.
[35]
External
External interlock function has been
Interlock
activated via 1 of the digital inputs.
[40]
Out of ref
range
[41]
Below
reference low
[42]
Above
reference high
[45]
Bus Ctrl
[46]
Bus Ctrl 1 if
timeout
[47]
Bus Ctrl 0 if
timeout
[55]
Pulse output
[60]
Comparator 0
See parameter group 13-1* Comparators. If
comparator 0 is evaluated as true, the
output goes high. Otherwise, it is low.
[61]
Comparator 1
See parameter group 13-1* Comparators. If
comparator 1 is evaluated as true, the
output goes high. Otherwise, it is low.
[62]
Comparator 2
See parameter group 13-1* Comparators. If
comparator 2 is evaluated as true, the
output goes high. Otherwise, it is low.
[63]
Comparator 3
See parameter group 13-1* Comparators. If
comparator 3 is evaluated as true, the
output goes high. Otherwise, it is low.
[64]
Comparator 4
See parameter group 13-1* Comparators. If
comparator 4 is evaluated as true, the
output goes high. Otherwise, it is low.
[65]
Comparator 5
See parameter group 13-1* Comparators. If
comparator 5 is evaluated as true, the
output goes high. Otherwise, it is low.
[70]
Logic Rule 0
See parameter group 13-4* Logic Rules. If
logic rule 0 is evaluated as true, the
output goes high. Otherwise, it is low.
[71]
Logic Rule 1
See parameter group 13-4* Logic Rules. If
logic rule 1 is evaluated as true, the
output goes high. Otherwise, it is low.
[72]
Logic Rule 2
See parameter group 13-4* Logic Rules. If
logic rule 2 is evaluated as true, the
output goes high. Otherwise, it is low.
[73]
Logic Rule 3
See parameter group 13-4* Logic Rules. If
logic rule 3 is evaluated as true, the
output goes high. Otherwise, it is low.
[74]
Logic Rule 4
See parameter group 13-4* Logic Rules. If
logic rule 4 is evaluated as true, the
output goes high. Otherwise, it is low.
[75]
Logic Rule 5
See parameter group 13-4* Logic Rules. If
logic rule 5 is evaluated as true, the
output goes high. Otherwise, it is low.
[80]
SL Digital
See parameter 13-52 SL Controller Action.
Output A
The output goes high whenever the smart
logic action [38] Set digital out A high is
MG20OB02