Danfoss VLT AQUA Drive FC 202 Programming Manual page 152

Software version: 3.30
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Description
16-16 Torque [Nm]
Range:
0
[-30000 -
Nm
30000
*
Nm]
3
3
16-17 Speed [RPM]
Range:
0 RPM
[-30000 - 30000 RPM]
*
16-18 Motor Thermal
Range:
0 %
[0 -
*
100 %]
16-19 KTY sensor temperature
Range:
0 °C
[0 - 0 °C] Returning the actual temperature on KTY
*
16-20 Motor Angle
Range:
0 N/A
[0 - 65535
*
N/A]
16-22 Torque [%]
Range:
0 %
[-200 -
200 %]
*
150
VLT
Function:
View the torque value with sign, applied to
the motor shaft. Linearity is not exact
between 110% motor current and torque in
relation to the rated torque. Some motors
supply more than 160% torque. Therefore, the
minimum and the maximum values depend
on the maximum motor current and the
motor used. The value is filtered, and thus
approximately 1.3 s may pass from when an
input changes value to when the data
readout values change.
Function:
View the actual motor RPM.
Function:
View the calculated thermal load on the motor.
The cutout limit is 100%. The basis for
calculation is the ETR function selected in
parameter 1-90 Motor Thermal Protection.
Function:
sensor built into the motor.
See parameter group 1-9* Motor Temperature.
Function:
View the current encoder/resolver angle
offset relative to the index position. The
value range of 0–65535 corresponds to
0–2xpi (radian).
Function:
This is a readout parameter only.
Shows the actual torque yielded in percentage of
the rated torque, based on the setting of the
motor size and rated speed in
parameter 1-20 Motor Power [kW] or
parameter 1-21 Motor Power [HP], and
parameter 1-25 Motor Nominal Speed.
This is the value monitored by the broken-belt
function set in parameter group 22-6* Broken Belt
Detection.
Danfoss A/S © 05/2018 All rights reserved.
®
AQUA Drive FC 202
16-23 Motor Shaft Power [kW]
Range:
0 kW
[0 - 10000
*
kW]
16-24 Calibrated Stator Resistance
Range:
0.0000 Ohm
16-26 Power Filtered [kW]
Range:
0 kW
*
16-27 Power Filtered [hp]
Range:
0 hp
*
3.15.3 16-3* Drive Status
16-30 DC Link Voltage
Range:
0 V
[0 - 10000 V] View a measured value. The value is filtered
*
16-32 Brake Energy /s
Range:
0 kW
[0 - 10000 kW] View the brake power transmitted to an
*
16-33 Brake Energy Average
Range:
0 kW
[0 - 10000
*
kW]
16-34 Heatsink Temp.
Range:
0 °C
[0 -
*
255 °C]
16-35 Inverter Thermal
Range:
0 %
[0 - 100 %] View the thermal load on the inverter. The
*
Function:
Shows the power applied to the motor
shaft. The shown value is an estimate
based on the motor shaft torque and
motor speed.
Function:
[0.0000 - 100.0000
Shows the calibrated
*
Ohm]
stator resistance.
[0 - 10000 kW]
[0 - 10000 hp]
Function:
with a 30 ms time constant.
Function:
external brake resistor, stated as an
instant value.
Function:
View the brake power transmitted to an
external brake resistor. The mean power is
calculated on an average level based on the
selected time period within
parameter 2-13 Brake Power Monitoring.
Function:
View the frequency converter heat sink
temperature. The cutout limit is 90 ±5 °C (194
±9 °F), and the motor cuts back in at 60
±5 °C (140 ±9 °F).
Function:
cutout limit is 100%.
Function:
Function:
MG20OB02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents