3.24.10 27-6* Digital Inputs
Parameters for configuring digital inputs. Parameters in this
group are only available if VLT
Controller MCO 102 is installed.
27-60 Terminal X66/1 Digital Input
Select the function for this digital input.
Option:
[0]
No operation
*
[1]
Reset
[2]
Coast inverse
[3]
Coast and reset inv
[5]
DC-brake inverse
[6]
Stop inverse
[7]
External Interlock
[8]
Start
[9]
Latched start
[10]
Reversing
[11]
Start reversing
[14]
Jog
[15]
Preset reference on
[16]
Preset ref bit 0
[17]
Preset ref bit 1
[18]
Preset ref bit 2
[19]
Freeze reference
[20]
Freeze output
[21]
Speed up
[22]
Speed down
[23]
Set-up select bit 0
[24]
Set-up select bit 1
[34]
Ramp bit 0
[36]
Mains failure inverse
[37]
Emergency Mode
[42]
Ref source bit 0
[51]
Hand/Auto Start
[52]
Run permissive
[53]
Hand start
[54]
Auto start
[55]
DigiPot increase
[56]
DigiPot decrease
[57]
DigiPot clear
[62]
Reset Counter A
[65]
Reset Counter B
[66]
Sleep Mode
[75]
MCO Specific
[78]
Reset Preventive Maintenance Word
[80]
PTC Card 1
[85]
Latched Pump Derag
[86]
Flow Confirmation
[87]
Reset Flow Totalized Volume Counter
[88]
Reset Flow Actual Volume Counter
[89]
Reset Derag Counter
[120]
Lead Pump Start
[121]
Lead Pump Alternation
MG20OB02
Programming Guide
®
Advanced Cascade
Function:
Danfoss A/S © 05/2018 All rights reserved.
27-60 Terminal X66/1 Digital Input
Select the function for this digital input.
Option:
[130]
Pump 1 Interlock
[131]
Pump 2 Interlock
[132]
Pump 3 Interlock
[133]
Pump 4 Interlock
[134]
Pump 5 Interlock
[135]
Pump 6 Interlock
[136]
Pump 7 Interlock
[137]
Pump 8 Interlock
[138]
Pump 9 Interlock
27-61 Terminal X66/3 Digital Input
This parameter contains all options and functions listed in
parameter 27-60 Terminal X66/1 Digital Input.
27-62 Terminal X66/5 Digital Input
This parameter contains all options and functions listed in
parameter 27-60 Terminal X66/1 Digital Input.
27-63 Terminal X66/7 Digital Input
This parameter contains all options and functions listed in
parameter 27-60 Terminal X66/1 Digital Input.
27-64 Terminal X66/9 Digital Input
This parameter contains all options and functions listed in
parameter 27-60 Terminal X66/1 Digital Input.
27-65 Terminal X66/11 Digital Input
This parameter contains all options and functions listed in
parameter 27-60 Terminal X66/1 Digital Input.
27-66 Terminal X66/13 Digital Input
This parameter contains all options and functions listed in
parameter 27-60 Terminal X66/1 Digital Input.
Function: