Parameter Description

3.7 Parameters 5-** Digital In/Out

Parameter group for configuring the digital input and
output.
3.7.1 5-0* Digital I/O Mode
3
3
Parameters for configuring the input and output using
NPN and PNP.
5-00 Digital I/O Mode
Option:
[0]
PNP - Active
*
at 24V
[1]
NPN - Active
at 0V
5-01 Terminal 27 Mode
Option:
[0]
Input
*
[1]
Output Defines terminal 27 as a digital output.
5-02 Terminal 29 Mode
Option:
[0]
Input
*
[1]
Output Defines terminal 29 as a digital output.
3.7.2 5-1* Digital Inputs
Parameters for configuring the input functions for the
input terminals.
The digital inputs are used for selecting various functions
in the frequency converter. All digital inputs can be set to
the following functions:
76
Function:
NOTICE
This parameter cannot be adjusted
while the motor is running.
Digital inputs and programmed digital
outputs are pre-programmable for operation
either in PNP or NPN systems.
Action on positive directional pulses (0). PNP
systems are pulled down to GND.
Action on negative directional pulses (1).
NPN systems are pulled up to +24 V,
internally in the frequency converter.
Function:
NOTICE
This parameter cannot be adjusted while
the motor is running.
Defines terminal 27 as a digital input.
Function:
NOTICE
This parameter cannot be adjusted while
the motor is running.
Defines terminal 29 as a digital input.
Danfoss A/S © 05/2018 All rights reserved.
®
VLT
AQUA Drive FC 202
Options [120]–[138] are related to the cascade controller
functionality. For more information, see parameter group
25-** Cascade Controller.
Digital input function
No operation
Reset
Coast inverse
Coast and reset inverse
DC-brake inverse
Stop inverse
External interlock
Start
Latched start
Reversing
Start reversing
Jog
Preset reference on
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Set-up select bit 0
Set-up select bit 1
Pulse input
Ramp bit 0
Mains failure inverse
Ref source bit 0
Hand/auto start
Run permissive
Hand start
Auto start
DigiPot increase
DigiPot decrease
DigiPot clear
Counter A (up)
Counter A (down)
Reset counter A
Counter B (up)
Counter B (down)
Reset counter B
Sleep mode
Reset maintenance word
PTC card 1
Latched pump derag
Lead pump start
Lead pump alternation
Pump 1 interlock
Pump 2 interlock
Option
Terminal
[0]
19, 29, 32, 33
[1]
All
[2]
27
[3]
All
[5]
All
[6]
All
[7]
All
[8]
All
[9]
All
[10]
All
[11]
All
[14]
All
[15]
All
[16]
All
[17]
All
[18]
All
[19]
All
[20]
All
[21]
All
[22]
All
[23]
All
[24]
All
[32]
29, 33
[34]
All
[36]
All
[42]
All
[51]
All
[52]
All
[53]
All
[54]
All
[55]
All
[56]
All
[57]
All
[60]
29, 33
[61]
29, 33
[62]
All
[63]
29, 33
[64]
29, 33
[65]
All
[66]
All
[78]
All
[80]
All
[85]
All
[120]
All
[121]
All
[130]
All
[131]
All
MG20OB02