Table 10-1 System Setup Screen Item Descriptions (Continued)
Software Version
Company Name
Manual Standby Duration
Timer
Manual Boost Duration Timer
Remote Standby Duration
Timer
Remote Standby Delay Timer
Remote Standby Input Mode
Remote Boost Duration Timer
Remote Boost Delay timer
Remote Boost Input Mode
Language
Force Temperature Units To
Units
Date and Time
Time Zone
Automatic Daylight Saving
Interval
System Setup Screen
v 1.1 — July 2015
Item
The Current Software Version is for informational purposes only.
Husky support may ask for this number when troubleshooting or
upgrading Altanium.
Company name displayed on the status bar.
Zone temperature decreases for a given time duration or until a
set standby temperature is achieved.
Zones temperature increases for a given time duration or until a
set boost temperature is achieved.
Once an external signal has activated the remote standby mode,
the system cools down to the remote standby setpoint for the
duration of the timer setting.
Once an external signal has activated the remote standby mode,
the system waits for a set period of time (delay period) until
cooling down to the remote standby setpoint.
The standby setting is enabled based on one of three settings:
trigger, on/off, or direct.
Trigger: Includes a delay timer and duration timer. If the D/I signal
is lost, Standby or Boost mode continues until the duration timer
elapses.
On/Off: Includes a delay timer. If the D/I signal is lost, the controller
returns to the running state.
Direct: System enters Standby until the input signal is not active. If
the input signal is active when the system is started it will
immediately go into standby mode. Includes a delay timer.
Once an external signal has activated the remote boost mode, the
system heats up to the remote boost setpoint for the duration of
the timer setting.
The system will initiate the remote boost mode after a set period
of time.
The boost setting is enabled based on one of three settings: a
trigger, an on/off setting, or a direct signal.
Language displayed on the user interface.
Forces the temperature units to specified settings.
Units of measure (SI or Imperial) displayed on the user interface.
Current date and time displayed on the user interface.
Current time zone displayed on the user interface.
Automatic daylight savings on/off check box.
Specifies in seconds how often the process data will be sampled.
System Setup Screen