Table 10-1 System Setup Screen Item Descriptions (Continued)
Bake Out Limit
Bake Out Power
Bake Out Time Per Cycle
Number of Bake Out Cycles
Bake Out Setpoint
At Bake Out Temperature
Window
Heat to Bake Out Setpoint
Timeout
Display Thermocouple
Reading for Manual Zones
Allow Monitor Regulation for
Selection
Exclude Monitor Zones from
At-Temperature
Auto Slave Enable
Auto Slave Power Limit
Soft Start Enable
Soft Start Minimum Limit
System Setup Screen
v 1.1 — July 2015
Item
The system uses this value to assess whether a bake-out condition
exists. Upon system startup, if any zone exceeds this limit, the
system will enter bake-out mode.
For ICC
value is 0.2 amps.
For ICC
default value is 200 milliamps.
The system uses this value during the bake out process.
The parameter range is 0 to 25%. The default value is 5%.
Length of the bake out cycle. The parameter range is 1 to 30
minutes. The default value is 5 minutes.
The number of attempts to bake out the moisture in a heater. The
parameter range is 1 to 5. The default value is 1.
Specifies the bake out setpoint the zones must achieve during the
bake out process. The default value is 100°C (212°F). Displays only
if ICC
During the bake out process, this parameter specifies the
threshold that all zones must achieve before the bake out cycle
value starts counting down. The default value is 5°C (9°F). Displays
only if ICC
Specifies the amount of time the zones are given to achieve the
bake out setpoint. If the time period expires, a warning message
displays the problem and what happens when the warning
message is acknowledged. Displays only if ICC
A global setting that controls whether the controller view screens
display the thermocouple readings for zones in manual mode.
Enables the parameter that allows the change of the regulation
mode to "Monitor" for any zones in the Quick Set screen.
Enables the parameter that allows the exclusion of any zones set
to "Monitor" regulation from the at-temperature determination
by the system.
Toggle this parameter on or off.
This value is the limit used by the Auto Slave routine to determine
if the average power output of a candidate zone is within the
acceptable deviation of the slaved zone.
Toggle this parameter on or off. If this parameter is on, the soft
start process is applied upon startup.
Once the soft start process is initiated, the system calculates the
difference between the zone with the highest and lowest
temperatures. If this difference is less than this parameter value,
then this parameter value is applied to the soft start process.
Description
2
cards, the parameter range is 0 to 5 amps. The default
3
cards, the parameter range is 1 to 999 milliamps. The
3
cards are installed.
3
cards are installed.
System Setup Screen
3
cards are installed.
111