7.5.6 Remote Standby Fields

Temperature Setpoint
Temperature Minimum
Temperature Maximum
Power Setpoint
Power Minimum
Power Maximum

7.5.7 Remote Boost Fields

Temperature Setpoint
Temperature Minimum
Temperature Maximum
Power Setpoint
Power Minimum
Power Maximum
Remote Standby Fields
v 1.1 — July 2015
Item
Remote standby is initiated via a digital input signal from the IMM. This
setting lowers all zones to their remote standby setpoint until the timer
expires or the input is inactive. Possible values are 0 to 500°C or 32 to
932°F. The default value is 121°C or 250°F.
Limits the range that can be entered for Remote Standby Temperature.
Remote standby is initiated via a digital input signal from the IMM. This
setting lowers all zones to their remote standby setpoint until the timer
expires or the input is inactive. Possible values are 0% – 100%. The default
value is 10%.
Limits the range that can be entered for Remote Standby Power
Item
Remote boost is initiated via a digital input signal from the IMM. This
setting raises all zones to their remote boost setpoint until the timer
expires or the input is inactive. Possible values are 0 to 500°C or 32 to
932°F. The default value is No Change.
Limits the range that can be entered for Remote Boost Temperature.
Remote boost is initiated via a digital input signal from the IMM. This
setting raises all zones to their remote boost setpoint until the timer
expires or the input is inactive. Possible values are 0% – 100%. The default
value is 90%.
Limits the range that can be entered for Remote Boost Power.
Making Adjustments
Description
Description
69