Table 10-1 System Setup Screen Item Descriptions (Continued)
Energy Cost Rate
Currency Type
Grid Size
Group Offset
Wattage Voltage
Supply Configuration
Alarm Sensitivity
Maximum Temperature Limit
No Response Limit
At Temperature Minimum
Limit
Mold Cooling Enable Limit
Part Counting
Remote Load
SPI
112
v 1.1 — July 2015
Item
Energy cost accumulated per Kwh.
Currency for energy cost rate.
To change the mainframe layout on the Card Layout screen,
change the grid size.
Use the group offset setting to configure the linked systems. The
default group offset setting is 96 zones.
Insert the designed voltage rating of the heaters so the system can
accurately calculate Watt Voltage.
Used to select the supply configuration parameter: Delta 3PH,
Wye 3PH+N, Single Phase, or Integrated TX.
The duration of time the system has to stay in an error condition
before it is declared an alarm.
The number of degrees over the setpoint the Maximum
Temperature Alarm is activated.
A global setting that determines how long the system should
apply 96% power or greater without a 5 degree rise in
temperature before it is declared an alarm condition.
Defines the minimum threshold for activating the At-
Temperature signal.
Defines the threshold the system uses to determine when to
activate or deactivate the Mold Cooling Enable output.
Used to automatically count up parts with the ability to set a sack
full limit.
Used to select the mold setups that can be loaded directly from
the injection molding machine.
If a device is attached to the SPI connector, this section allows the
user to enable communication with the device and set
communication protocol.
Altanium Matrix2
Description
System Setup Screen