Use the Inputs screen to configure the digital input signals from the injection molding
machine.
Inputs
v 1.1 — July 2015
Item
Set this to enable the signal. When enabled, the controller will read or set the
signal according to the signal description in
Section
16.6.2.
The current state of the input or output.
Name given to the input or output signal by the user. This name is used
throughout the system.
Defines the type of output signal. The choices are Function, Configurable or
None.
Defines what output signals are available for selection based on the signal
type selected. The signal selected determines the function of the output.
Name of the function that the input signal performs.
The inputs and outputs can be set as normally open or normally closed:
To set to normally open, select Open (default)
When set as normally open:
To set to normally closed, select Closed
When set as normally closed:
Indicates the electrical state of the input or output at the pin on the
connector on the outside of the UltraSync-E controller. This equals the
logical state after the input or output has been inverted by a Normally Close
signal.
Text fields that indicate the connector and pins that the input or output
signal is physically wired to on the outside of the UltraSync-E controller.
Description
Inputs: Active when input gets 24V
Outputs: Active state will close the relay output
Inputs: Active when input gets 0V
Outputs: Active state will open the relay output.
UltraSync-E, If Equipped
Section 16.6.1
and
205