Husky Altanium Matrix2 User Manual page 59

Table of Contents

Advertisement

User Guide
Soft Start Setup
Mold Setup Auxiliary
Actions
Mold Setup Load
Action
Mold Setup Save
Action
Quick Set Advanced
Options
Quick Set
Temperature
Setpoints Options
Quick Set Standby
and Boost Setpoints
Options
Earth Leakage Fault
Enable
Earth Leakage Fault
Setup
Bake Out Enable
Bake Out Setup
Thermocouple
Reading
Power Deviation
Zone Slot
Configuration
Zone Alarm Control
Settings
Mold Cooling Enable
Limit
User Management and Security Screens
v 1.1 — July 2015
Item
Permission to set up soft start on the System Setup screen.
Permission to view files (mold setups, images, txt files and PDF documents)
and operate the following buttons on the Mold Setup screen: Create
Folder, Delete, Copy, Paste, and Rename.
Permissions to load a mold setup configuration file and to create a new
mold setup configuration file on the Mold Setup screen.
Permission to save changes to mold setup files and use the Save As
function on the Mold Setup screen.
Permissions to make changes to the fields in the following sections on the
Quick Set screen: Frequently Used, Zone Edit, Advanced Options, and
Control Settings.
Permission to change the fields in the Setpoint Limit Section on the Quick
Set screen.
Permission to change the fields in the Manual Standby, Manual Boost,
Remote Standby and Remote Boost sections on the Quick Set screen.
Permission to select and clear the System Earth Leakage Enable check
box on the System Setup screen.
Permission to operate the following fields on the System Setup screen:
Earth Leakage Fault Enable checkbox
Earth Leakage Limit field
Display Earth Leakage Reading check box
Circuit Overload Enable check box
Circuit Test Enable check box
Permission to enable the bake out function on the System Setup screen.
Permission to configure the bake out function on the System Setup
screen.
Permission to select and clear the Display Thermocouple Reading for
Manual Zones check box on the System Setup screen.
Permission to select the Setup Alarm button in the Power Deviation
section on the System Setup screen.
Permissions to operate the Zone Slot Configuration fields on the System
Setup screen and the fields on the Zone Slot Configuration screen.
Permission to configure all the parameters in the Zone Alarm Control area
of the System Setup screen.
Permission to change this parameter in the Mold Cooling Enable area of
the System Setup screen.
Security and Administration
Description
47