16.4.3.3 Tool

Use the Tool dialog box to configure the UltraSync controller for the hot runner tool it is
actuating. These settings can only be changed in Disabled mode.
Each motor is associated with a parameter set. Operation of UltraSync-E is not allowed until
the parameter set of the selected motor has been downloaded and saved to the servo drive,
and a power cycle of the Matrix2 controller is performed by restarting the entire Matrix2
controller.
To perform a parameter set download, select the desired motor and touch the Download
button.
The status of the active parameter set is displayed in a text box as follows:
Download Required
Downloading
System Restart Required
Ready
Figure 16-6 Tool Dialog Box
200
v 1.1 — July 2015
Status
Description
The parameter set in the drive does not match
the selected motor and a parameter set
download is required.
The parameter set of the selected motor is being
downloaded to the drive.
The parameter set in the drive matches the
selected motor, but a power cycle is required
before it can be used.
The parameter set matches the selected motor
and is ready to run.