16.6.2 Outputs

Use the Outputs screen to configure the digital output signals to the injection molding
machine.
Figure 16-11 Digital Outputs Screen
IMM Signal Reference
Fault Stop Immediate
Ready and Engaged
Valve Stems at Open
Valve Stems at Close
Outputs
v 1.1 — July 2015
Signal Name
Reference signal from IMM for dry contacts.
Active when clamp motion is permitted. These
contacts are opened when an immediate stop is
required for the machine, due to a fault or alarm on
the controller.
Active when controller is enabled with no faults, in
auto/engaged mode.
Active when all of the following conditions are true:
-Valve gate controller is ready and engaged
-Valve stems are at open position
-Valve gate controller is in auto/engaged mode
This signal can be used to provide injection
permission to the IMM.
Active when valve gate stems are at closed position,
and controller is enabled.
UltraSync-E, If Equipped
Description
Pin (s)
5, 6
7, 8
6, 9
6, 10
6, 11