User Guide
To change the remote standby input mode, do the following:
1.
2.
NOTE:
10.1.7.5 Standby Operation Description
Table 10-2 Manual Standby Operational Description
Manual
Time
0:00:00
X:XX:XX
To cancel the manual standby duration timer at any time, touch the Start or Stop buttons.
Table 10-3 Remote Standby Operational Description
Manual
Time
----
----
----
----
----
----
Standby Operation Description
On the System Setup screen, under Remote Standby, touch the Remote Standby
Input Mode field.
Select the desired setting.
This setting will not appear if the remote standby option is not available on the
system.
Delay
Remote
Time
Time
----
----
----
----
Delay
Remote
Time
Time
0:00:00
0:00:00
0:00:00
X:XX:XX
X:XX:XX
X:XX:XX
X:XX:XX
0:00:00
X:XX:XX
X:XX:XX
X:XX:XX
0:00:00
v 1.1 — July 2015
Input
Cycle
Mode
Enabled
----
----
----
----
Input
Cycle
Mode
Enabled
Trigger
----
Trigger
----
Trigger
No
Trigger
No
Trigger
Yes
Trigger
Yes
System Setup Screen
Operation - STANDBY Button
Select
System enters Standby indefinitely.
System remains in Standby until the
timer expires.
Operation - STANDBY Button
Select
System will not enter Standby since no
timers are set.
System immediately enters and
remains in Standby until the timer
expires.
System delays for specified time and
then enters Standby until the timer
expires.
System delays for specified time and
then enters Standby indefinitely.
System delays for specified time and
then enters Standby until the timer
expires. If the input signal changes
state while delay timer is active, the
delay timer is reset to the specified
value.
System delays for specified time and
then enters Standby indefinitely. If the
input signal changes state while the
delay timer is active, the delay timer is
reset to the specified value.
117
Need help?
Do you have a question about the Altanium Matrix2 and is the answer not in the manual?