Alarm 1 Setpoint
v 1.1 — July 2015
This command is used to set and read the alarm window value for a
single zone. The alarm window is used only for zones with Auto or View
regulation.
The following conditions result in a NAK response with an invalid data
error for the select function:
Incorrect data length.
Invalid zone number.
A value less than 0 °F or greater than 900 °F.
A value greater than the abort window value.
The following conditions result in an invalid data error in response to a
polled function:
Invalid zone number.
This command is used to set and read the abort window value for a
single zone. The abort window is used only for zones with Auto or View
regulation.
The following conditions result in a NAK response with an invalid data
error for the select function:
Incorrect data length.
Invalid zone number.
A value less than 0 °F or greater than 900 °F.
A value greater than the abort window value.
The following conditions result in an invalid data error in response to a
polled function:
Invalid zone number.
This command is used to clear the errors for all the zones in the system.
The system does not have the ability to clear an error for an individual
zone.
The following conditions result in a NAK response with an invalid data
error for the select function:
Incorrect data length.
Invalid zone number.