Line
Line
DANGER!
Electrocution and/or mechanical hazard - risk of death or serious injury and possible
damage to the equipment.
Incorrectly wiring the controller could cause death or serious injury and/or damage to
the controller or hot runner. Only qualified personnel should connect the electrical
power supply. All work must conform to applicable local electrical codes.
1.5

Environmental Operating Specification

For Indoor use only.
1.6

Equipment Ratings

Ratings for the entire Altanium Controller can be found on the nameplate attached to the
back of the controller.
The following are the equipment ratings for the Altanium Matrix2 Operator Interface only:
1.7

Technical Specifications

The dimensions and weight of the controller can change based on the controller
configuration.
4
Description
Operating Temperature: 5 to 40 °C (41 to 104 °F)
Operating Humidity: 90% RH maximum
Altitude: up to 2000 m (6562 ft)
Pollution Degree: PD2
Overvoltage Category: OVIII
Supply Voltage: 100 to 240 VAC +/- 10%, single phase
Frequency: 47 to 63 Hz
Power Rating: 100 W (typical)