9.4.2 Alarm States

Alarm states are as follows:
Active
Inactive Not
Acknowledged
Inactive Acknowledged

9.4.3 Clearing Alarms

If an error occurs, Altanium will turn on audible and visual alarms and display the alarm
condition on the Alarm screen.
To clear an alarm, do the following:
NOTE:
Figure 9-2 Silencing an Audible or Visual Alarm
1. Silence Horn Button 2. Reset Alarms Button 3. Clear Inactive Alarms Button
100
Alarm State
When an alarm first occurs it is assigned the active state.
Press the Reset Alarms button and the alarm will be assigned the inactive
not acknowledged state.
Press the Clear Inactive Alarms button and the alarm will be assigned the
inactive acknowledged state.
Before resetting an alarm, correct the source of the alarm.
To silence an audible alarm, touch the Silence Horn button.
To reset the alarm light and acknowledge the alarm, touch the Reset Alarms button.