Table 10-1 System Setup Screen Item Descriptions (Continued)
License Number
Update License
View License
Power Deviation
Power Limiting
Log Transfer
Earth Leakage Fault Enable
Earth Leakage Limit
Earth Leakage Fault Limit
Default Value
Earth Leakage Minimum Limit
Display Earth Leakage Reading Enables earth leakage displays when ICC
Circuit Overload Enable
Circuit Test Enable
Bake Out Enable
Force Bake Out Enable
Bake Out Alert Enable
110
v 1.1 — July 2015
Item
License key is displayed.
Upload new license file from local, USB, and network drives.
Display license information.
Toggle this parameter on or off. If this parameter is toggled on, a
power deviation will trigger a power deviation alarm.
Controls the maximum output power delivered to each zone.
Transfer data log or event log in CSV format to specified log file
destination. The entire log is transferred or a time range can be
set.
Toggle this parameter to turn earth leakage checking on or off.
For ICC
limit once the diagnostic process for a zone is complete. The
control card uses a percentage of the current measured during
the test to determine when to declare an earth leakage error.
The parameter range is 0 to 100%. The default value is 10%.
For ICC
adjustable range from 1 to 999 mA. The default value is 500 mA.
The value the system will use to determine the earth leakage limit
if diagnostics have not been run on a zone. Only displayed if ICC
cards are installed.
The parameter range is 0.0 to 5.0 amps. The default value is 0.2
amps.
The minimum earth leakage limit value. Only displayed if ICC
cards are installed.
Enables or disables the circuit overload error. Displays only if ICC
cards are installed.
Enables the circuit test for ICC
If this parameter is enabled, the system will run the bake out test
and apply a low voltage to remove the moisture in a heater if
required. Toggle this parameter on or off.
Toggle this parameter on or off. If this parameter is on, each zone
in the system is baked out upon startup.
If this parameter is enabled, the system stops and generates an
alarm for each zone with a bake-out condition that has not been
cleared during the bake out cycle.
If this parameter is disabled, the system exits the existing bake-out
cycle and continues the startup sequence.
Description
2
cards, a percentage used to calculate the earth leakage
3
cards, the value is displayed in milliamps and has an
3
cards.
Altanium Matrix2
2
2
3
cards are installed.
3
System Setup Screen