Vacon optea Installation Manual page 141

Advanced/dual port ethernet board
Hide thumbs Also See for optea:
Table of Contents

Advertisement

EtherNet/IP
Name
SHORT_STRING *
BYTE
WORD
DWORD
LWORD
* ISO/IEC-8859-1 encoding.
9.1.5.2
General CIP error codes
The following table contains the error codes used by the EtherNet/IP implementation.
Code
Status name
0
Success
1
Connection failure
2
Resource unavailable
Invalid parameter
3
value
4
Path segment error
Path destination
5
unknown
6
Partial transfer
8
Service not supported
9
Invalid attribute value Invalid attribute data detected.
12
/ 0C
Object state conflict
d
h
14
/ 0E
Attribute not settable A request to modify a non-modifiable attribute was received.
d
h
15
/ 0F
Privilege violation
d
h
16
/ 10
Device state conflict
d
h
17
/ 11
Reply data too large
d
h
19
/ 13
Not enough data
d
h
Attribute not sup-
20
/ 14
d
h
ported
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
Table 107. EtherNet/IP datatypes
Description
Character string (1 octet
per char., 1 octet length
indicator)
Bit string (8 bits)
Bit string (16 bits)
Bit string (32 bits)
Bit string (64 bits)
Table 108. General CIP error codes
Service was successfully performed by the object specified.
A connection related service failed along the connection path.
Resources needed for the object to perform the requested
service were unavailable.
See Status Code 0x20, which is the preferred value to use for
this condition.
The path segment identifier or the segment syntax was not
understood by the processing node.
The path is referencing an object class, instance or structure
element that is not known or is not contained in the process-
ing node.
Only part of the expected data was transferred.
The requested service was not implemented or was not
defined for this Object Class/Instance.
The object cannot perform the requested service in its cur-
rent mode/state.
A permission/privilege check failed.
The device's current mode/state prohibits the execution of
the requested service.
The data to be transmitted in the response buffer is larger
than the allocated response buffer.
The service did not supply enough data to perform the speci-
fied operation.
The attribute specified in the request is not supported.
Bit size
Range
Minimum Maximum
N+1
8
16
32
64
Description
vacon • 141
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opte9

Table of Contents