vacon • 122
8.4.6.3
PROFIdrive Parameter Access errors
In addition to the error indications in the error response field, details about the error are provided
in the parameter value field. The third octet in the parameter value is set to 0x00 and the fourth octet
is assigned the error number, as described in Table 86.
Error number Meaning
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C...0x0E
0x0F
0x10
0x11
0x12...0x13
0x14
0x15
0x16
0x17
0x18
0x19
8
Table 86. PROFIdrive parameter access errors
Impermissible parameter
number
Parameter value cannot be
changed
0x0 = invalid index
Invalid subindex
Non-array parameter
Incorrect data type
Setting not permitted (may
only be reset)
Description element cannot
be changed
Reserved (not used)
No description data avail-
able
Reserved (not used)
No operation priority
Reserved (not used)
No text array available
Reserved (not used)
Request cannot be executed
Reserved (not used)
Value impermissible
Response too long
Impermissible parameter
address
Illegal format
Number of values are not
consistent
Axis non-existent
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
When used
Access to unavailable parameter.
Change request to a read-only parameter.
0xB0 = parameter requests are not supported.
Access to an unavailable subindex of an array pa-
rameter.
Attempt to access subindex of a non-array parame-
ter.
Change request containing invalid data type for the
accessed parameter.
Change request to a non-zero value, where this is
not allowed.
Change request to a read-only parameter descrip-
tion element.
Access to unavailable parameter description.
Change request without access rights to perform
the change.
Access to unavailable parameter text array.
Access is temporarily not possible due to unspeci-
fied reasons.
Change request with a value within the allowed
range, but is otherwise not permissible.
The length of the respose exceeds the maximum
transmittable length.
Error in the parameter address field.
Illegal format was provided in write request.
The number of values in the write request does not
match the number of values in the parameter.
Access to non-existent axis number