Display Poe-Power - HPE FlexNetwork 7500 Series Command Reference Manual

Network management and monitoring
Table of Contents

Advertisement

Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
pse pse-id: Specifies a PSE by its ID. To display PSE ID and slot mappings, use the display poe
device command.
Usage guidelines
Only the default MDC supports this command.
Examples
# Display power information for PIs on PSE 4.
<Sysname> display poe pse 4 interface power
Interface
GE1/0/25
GE1/0/26
GE1/0/27
GE1/0/28
GE1/0/29
GE1/0/30
---
On State Ports: 3; Used: 23.8(W);
Table 30 Command output
Field
Interface
Current
Peak
Max
PD Description
Ports On
Used
Remaining

display poe-power

Use display poe-power to display PoE power information.
Syntax
In standalone mode:
display poe-power
Current
Peak
(W)
(W)
4.4
4.5
4.4
4.5
15.0
15.3
0.0
0.0
0.0
0.0
0.0
0.0
Max
PD Description
(W)
4.6
IP Phone on Room 309 for Peter Smith
15.4
IP Phone on Room 409 for Peter Pan
15.4
Access Point on Room 509 for Peter
5.0
IP Phone on Room 609 for Peter John
4.0
IP Phone on Room 709 for Jack
5.0
IP Phone on Room 809 for Alien
Remaining: 776.2(W) ---
Description
Interface name of a PI.
Current power of a PI.
Peak power of a PI.
Maximum power of a PI.
Type and location description for the PD connected with a PI.
Number of PIs that are supplying power.
Power consumed by all PIs.
Remaining power on the PSE.
150