HPE FlexNetwork 7500 Series Command Reference Manual page 153

Network management and monitoring
Table of Contents

Advertisement

Field
Average Power
Peak Power
Max Power
Electric Current
Voltage
PD Description
# Display power supplying information for all PIs.
<Sysname> display poe interface
Interface
PoE
GE1/0/1
Enabled
GE1/0/2
Enabled
GE1/0/3
Enabled
GE1/0/4
Enabled
GE1/0/5
Enabled
GE1/0/6
Enabled
GE1/0/7
Disabled
---
On State Ports: 2; Used: 8.4(W); Remaining: 171.6(W)
Table 25 Command output
Field
Interface
PoE
Priority
CurPower
Oper
IEEE Class
Description
Average power of a PI.
Peak power of a PI.
Maximum power of a PI.
Current of a PI.
Voltage of a PI.
Type and location description for the PD connected to the PI.
Priority
CurPower
(W)
Low
4.4
Critical
0.0
Low
0.0
Critical
0.0
Low
4.0
Low
0.0
Low
0.0
Description
Interface name of a PI.
PoE status:
Enabled.
Disabled.
Power priority of a PI:
Critical (highest).
High.
Low.
Current power of a PI.
Operating status of a PI:
Off—PoE is disabled.
On—Power is being supplied to the PI correctly.
Power-lack—Remaining guaranteed power is insufficient for a
critical PI.
Power-deny—The PSE refuses to supply power. The power
required by the PD is higher than the configured power.
Power-itself—The PD is using another power supply.
Power-limit—The PSE is supplying power to the PD based on
the configured power though the PD requires more power than the
configured power.
PD power class: 0, 1, 2, 3, or 4.
If the PSE does not support PD classification, this field displays a
hyphen (-).
143
Oper
IEEE
Detection
Class Status
On
1
Delivering Power
On
-
Disabled
On
-
On
-
Searching
On
2
On
-
Off
-
---
Disabled
Delivering Power
Disabled
Fault

Advertisement

Table of Contents
loading

Table of Contents