HPE FlexNetwork 7500 Series Command Reference Manual page 161

Network management and monitoring
Table of Contents

Advertisement

In IRF mode:
display poe-power [ chassis chassis-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
chassis chassis-number: Specifies an IRF member device by its member ID. If you do not specify a
member device, the command displays information about all PoE power supplies and PSEs in the
IRF fabric. (In IRF mode.)
Usage guidelines
Only the default MDC supports this command.
Examples
# Display PoE power information.
<Sysname> display poe-power
PoE Current Power
PoE Average Power
PoE Peak Power
PoE Max Power
PoE Nominal Power
PoE Current Electric Current
PoE Current Voltage
PoE Lower Input Threshold
PoE Upper Input Threshold
PoE Lower Output Threshold
PoE Upper Output Threshold
PoE Hardware Version
PoE Software Version
PoE Power Supplies
PoE Power Supply 1:
Manufacturer
Type
Status
PoE Power Supply 2:
Manufacturer
Type
Status
Table 31 Command output
Field
PoE Current Power
PoE Average Power
: 1870
W
: 2100
W
: 2350
: 2000
: 2500
: 3.00
A
: 55.00
: 111.22
V
: 131.00
V
: 45.00
V
: 57.00
V
: 0002
: 0001
: 2
: Tyco Electronics Com
: PSE2500-A
: Normal
: Tyco Electronics Com
: PSE2500-B
: Normal
Description
Current PoE power.
Average PoE power.
151
W
W
W
V

Advertisement

Table of Contents
loading

Table of Contents