Clock source: 192.168.1.40
Session ID: 35888
Clock stratum: 2
Clock status:
configured, master, sane, valid
Reference clock ID: 127.127.1.0
VPN instance: Not specified
Local mode: client, local poll interval: 6
Peer mode: server, peer poll interval: 6
Offset: 0.2862ms, roundtrip delay: 3.2653ms, dispersion: 4.5166ms
Root roundtrip delay: 0.0000ms, root dispersion: 10.910ms
Reachabilities:31, sync distance: 0.0194
Precision: 2^18, version: 3, source interface: Not specified
Reftime: d17cbba5.1473de1e
Orgtime: 00000000.00000000
Rcvtime: d17cbbc0.b1959a30
Xmttime: d17cbbc0.b1959a30
Roundtrip delay samples: 0.007 0.010 0.006 0.011 0.010 0.005 0.007 0.003
Offset samples: 5629.55 3913.76 5247.27 6526.92 31.99 148.72 38.27 0.29
Filter order: 7
Total sessions: 1
Table 18 Command output
Field
Clock source
Clock stratum
Clock status
Tue, May 17 2011
Thu, Feb
7 2036
Tue, May 17 2011
Tue, May 17 2011
5
2
6
0
Description
IP address of the NTP server. If this field displays 0.0.0.0, the IP address of the
NTP server has not been resolved successfully.
Stratum level of the NTP server, which determines the clock accuracy. The
value is in the range of 1 to 16. A lower stratum level represents greater clock
accuracy. A stratum 16 clock is not synchronized and cannot be used as a
reference clock.
Status of the clock source corresponding to this association:
configured—The association was created by a configuration command.
dynamic—The association is established dynamically.
master—The clock source is the primary reference source of the current
system.
selected—The clock source has survived the clock selection algorithm.
candidate—The clock source is the candidate reference source.
sane—The clock source has passed authentication and will be used as a
reference clock.
insane—The clock source has not passed authentication, or it has passed
authentication but will not be used as a reference clock.
valid—The clock source is valid, which means the clock source meets the
following requirements:
It has been authenticated and synchronized.
Its stratum level is valid.
Its root delay and root dispersion values are within their ranges.
invalid—The clock source is invalid.
unsynced—The clock source has not been synchronized or the value of
the stratum level is invalid.
101
9:17:25.079
6:28:16.000
9:17:52.693
9:17:52.693
4
1
3

Advertisement

Table of Contents
loading

Table of Contents