Field
Detection Status
On State Ports
Used
Remaining

display poe interface power

Use display poe interface power to display power information for PIs.
Syntax
display poe interface power [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
interface-type interface-number: Specifies an interface by its type and number. If you do not specify
an interface for the default MDC, this command displays power information for all PIs. This option is
required for non-default MDCs.
Examples
# Display power information for Ten-GigabitEthernet 1/0/1.
<Sysname> display poe interface power ten-gigabitethernet 1/0/1
Interface
GE1/0/1
# Display power information for all PIs.
<Sysname> display poe interface power
Interface
GE1/0/1
GE1/0/2
GE1/0/3
GE1/0/4
GE1/0/5
Description
Power detection status of a PI:
Number of PIs that are supplying power.
Power consumed by the current PI.
Total remaining power of the system.
Current
Peak
(W)
(W)
15.0
15.3
Current
Peak
(W)
(W)
4.4
4.5
4.4
4.5
15.0
15.3
0.0
0.0
0.0
0.0
Disabled—PoE function is disabled.
Searching—The PI is searching for the PD.
Delivering Power—The PI is supplying power for the PD.
Fault—A fault occurred during the test.
Test—The PI is undergoing a test.
Other fault—A fault has caused the PSE to enter the idle status.
PD disconnected—The PD is disconnected.
Max
PD Description
(W)
30.0
Access Point on Room 509 for Peter
Max
PD Description
(W)
30.0
IP Phone in Room 309 for Peter Smith
30.0
IP Phone in Room 409 for Peter Pan
30.0
Access Point in Room 509 for Peter
30.0
IP Phone in Room 609 for Peter John
30.0
IP Phone in Room 709 for Jack
144