Poe Update; Poe Utilization-Threshold - HPE FlexNetwork 7500 Series Command Reference Manual

Network management and monitoring
Table of Contents

Advertisement

Disables PoE on all ports when the temperature exceeds the upper limit.
Disables PoE on all ports when the temperature drops below the lower limit.
Examples
# Disable PoE over-temperature protection.
<Sysname> system-view
[Sysname] undo poe temperature-protection enable

poe update

Use poe update to upgrade the PSE firmware when the device is operating.
Syntax
poe update { full | refresh } filename [ pse pse-id ]
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
full: Upgrades the PSE firmware in full mode.
refresh: Upgrades the PSE firmware in refresh mode.
filename: Specifies the name of the upgrade file, a case-insensitive string of 1 to 64 characters. The
specified file must be in the root directory of the file system of the device.
pse pse-id: Specifies a PSE by its ID. If you do not specify a PSE, all PSEs are upgraded.
Usage guidelines
Only the default MDC supports this command.
You can upgrade the PSE firmware in service in either of the following modes:
Refresh mode—Updates the PSE firmware without deleting it. You can use the refresh mode
in most cases.
Full mode—Deletes the current PSE firmware and reloads a new one. Use the full mode if the
PSE firmware is damaged and you cannot execute any PoE commands.
Examples
# Upgrade the firmware of PSE 4 in service.
<Sysname> system-view
[Sysname] poe update refresh POE-168.bin pse 4

poe utilization-threshold

Use poe utilization-threshold to configure a power alarm threshold for the PSE.
Use undo poe utilization-threshold to restore the default power alarm threshold of the PSE.
Syntax
poe utilization-threshold value pse pse-id
undo poe utilization-threshold pse pse-id
164

Advertisement

Table of Contents
loading

Table of Contents