Diagnostic Simulation - HPE FlexNetwork 7500 Series Command Reference Manual

Network management and monitoring
Table of Contents

Advertisement

Default
The execution interval varies by monitoring diagnostic test. Use the display diagnostic content
command to view the execution interval for a test.
Views
System view
Predefined user roles
network-admin
Parameters
chassis chassis-number: Specifies an IRF member device by its member ID. (In IRF mode.)
slot slot-number-list: Specifies a space-separated list of up to seven slot number items. An item
specifies a card by its slot number or specifies a range of cards in the form of start-slot-number to
end-slot-number. The end slot number must be equal to or greater than the start slot number.
test test-name: Specifies a test by its name, a case-sensitive character string. You can use the test ?
command to verify the value range of the test name. If you do not specify this option, the command
applies to all monitoring diagnostic tests.
interval: Sets an execution interval in the form of hh:mm:ss. The value range for the hh argument is 0
to 23. The value range for the mm and ss arguments is both 0 to 59. If you specify only the hh
argument, you can omit the mm and ss segments. If you specify only the hh and mm arguments, you
can omit the ss segment. For example, to specify 01:00:00, you can enter 1.
Usage guidelines
Use this command to configure the interval at which the system automatically executes enabled
monitoring diagnostic tests.
The configured interval cannot be smaller than the minimum execution interval of the tests. Use the
display diagnostic content verbose command to view the minimum execution interval of the tests.
Examples
# (In standalone mode.) Set the execution interval to 1 minute for test BoardStatusMonitor on the
specified slot.
<Sysname> system-view.
[Sysname] diagnostic monitor interval slot 1 test BoardStatusMonitor time 00:01:00
Related commands
diagnostic monitor enable
display diagnostic content

diagnostic simulation

Use diagnostic simulation to simulate diagnostic tests.
Use undo diagnostic simulation to restore the default.
Syntax
In standalone mode:
diagnostic simulation slot slot-number-list test test-name { failure | random-failure | success }
undo diagnostic simulation slot slot-number-list test test-name
In IRF mode:
diagnostic simulation chassis chassis-number slot slot-number-list test test-name { failure |
random-failure | success }