Display Diagnostic Simulation - HPE FlexNetwork 7500 Series Command Reference Manual

Network management and monitoring
Table of Contents

Advertisement

test test-name: Specifies a test by its name, a case-sensitive character string. You can use the test ?
command to verify the value range of the test name. If you do not specify this option, the command
applies to all packet-related diagnostic tests.
Examples
# (In standalone mode.) Display statistics for test PortMonitor on the specified slot.
<Sysname> display diagnostic result slot 1 test PortMonitor statistics
Slot 1:
Test name: PortMonitor
Port
Packets sent
1
0
2
0
3
0
4
4
5
4
6
4
7
4
8
0
Table 94 Command output
Field
Test name
Port
Packets sent
Packets received
Packets lost

display diagnostic simulation

Use display diagnostic simulation to display configurations for simulated diagnostic tests.
Syntax
In standalone mode:
display diagnostic simulation [ slot slot-number ]
In IRF mode:
display diagnostic simulation [ chassis chassis-number [ slot slot-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify this option, the command
applies to all cards. (In standalone mode.)
Packets received
0
0
0
4
4
4
4
0
Description
Name of the test.
Port number.
Number of packets that the device sends.
Number of packets that the device receives.
Number of lost packets.
420
Packets lost
0
0
0
0
0
0
0
0

Advertisement

Table of Contents
loading

Table of Contents