Remove a Fan Module

/SYS/MB/FM0/F0/TACH
Properties:
value = 3100.000 RPM
->
where:
x is the fan module, 0 (left fan module) to 4 (right fan module).
y is the fan element, 0 (primary) or 1 (secondary).
If a fan module is faulty, replace it. See
6.
If you are unable to determine if a fan module is faulty, seek further information.
See
"Detecting and Managing Faults" on page
Related Information
"Remove a Fan Module" on page 132
"Fan Module LEDs" on page 130
"Verify a Fan Module" on page 136
"Detecting and Managing Faults" on page 21
Remove a Fan Module
Removing a fan module is a cold-service operation. You must power off the server before you
remove the fan module.
1.
Determine which fan module to remove.
See
"Locate a Faulty Fan Module" on page
2.
Consider your next step.
If you have not prepared for service, do so now. See
If you are removing a fan module as part of another component's removal or installation
procedure, go to
132
Netra Server X5-2 Service Manual • October 2016
"Remove a Fan Module" on page
131.
Step
3.
21.
"Preparing for Service" on page
132.
61.