Filler Panels
Antistatic mat
■
No. 1 Phillips screwdriver
■
No. 2 Phillips screwdriver
■
Related Information
"Safety Information" on page 62
■
"Component Service Task Reference" on page 65
■
"Accessing Internal Components" on page 71
■
Filler Panels
Servers might be shipped with replacement filler panels for hard drives and PCI cards. A filler
panel is an empty metal or plastic enclosure that does not contain any functioning system
hardware or cable connectors.
The filler panels are installed at the factory and must remain in the server until you replace
them with a functional component to ensure proper airflow through the system. If you remove
a filler panel and continue to operate your server with an empty slot, the server might overheat
due to improper airflow. For instructions on removing or installing a filler panel for a server
component, refer to the topic in this document about servicing that component.
Related Information
"Component Service Task Reference" on page 65
■
"Servicing SAS Drives" on page 93
■
"Servicing PCIe Cards" on page 137
■
Find the Server Serial Number
If you require technical support for your server, you must provide the chassis serial number.
You can find the chassis serial number on a sticker located on the front of the server and on
another sticker on the side of the server.
If it is not convenient to read either sticker, follow this procedure.
1.
Access Oracle ILOM.
64